Skip Navigation Linkssiliclinicianguid

occupational health branch

​​

Guidance for California Clinicians Performing Silicosis Medical Surveillance Exams Per Cal/OSHA’s Silica Regulation for General Industry (Title 8, § 5204)

​Summary

​Exam Requirements (see algorithm)

  1. Frequency: Initial and every 3 years (or more as needed)
  2. Components:
    • ​​Occupational and clinical history​
    • Physical Exam
    • Chest Imaging:
      • ​​​​​​For workers exposed to high exposure trigger tasks: Low-dose Chest CT
      • For other occupational exposure: Chest X-ray with B-read, or low-dose Chest CT if physician or other licensed health care professional (PLHCP) recommends. Note that a B read with a profusion score ≥1/0 is abnormal.​
    • ​Spirometry
    • Latent tuberculosis (TB) testing (initial exam only).
  3. Written Medical Opinion
    • ​​To Employer: Exam date, restrictions on respirator use, exposure limitations, need for specialist, and need for supplied air respirator

    • To Employee: All of above, and results of exam, health risks, and recommendations for evaluation/treatment.​

Supplied Air Respirator Guidance

  • ​Workers with suspected or confirmed silicosis must use a supplied-air respirator.

​Required Reporting

​​For more details,  refer to the full guidance document below, and consult Cal/OSHA’s silica regulation​ to ensure compliance.

Medical Surveillance Exam Requirements: See algorithm below

​Workers who meet the following criteria must be offered an initial exam and a periodic exam at least every 3 years (or more frequently if recommended by PLHCP) by their employer:

  1. Exposed to high-exposure trigger tasks for ≥30 days/year, regardless of exposure measurements, or
  2. Exposed to respirable crystalline silica at or above the action level for ≥30 days/year.

These exams must include:

  1. Clinical and occupational history (see employee questionnaire for an example template)
  2. ​Physical exam, with focus on respiratory system
  3. Chest imaging​​​​​​
    a. Low dose CT (LDCT) chest for workers who performed high exposure trigger tasks ≥30 days/year (Workers involved in countertop fabrication or similar tasks are likely to fall under this category), 
    i. What to order: A chest CT scan performed at the lowest dose possible, such as with a protocol similar to that used for lung cancer screening per American College of Radiology (ACR) / American Association of Physicists in Medicine (AAPM) guidelines (reference: Lung Cancer Screening CT Protocols Version 6.0 09 November 2023 (PDF)​). 
    ii. Important to inform radiologist that scan is to evaluate for silicosis.
    iii. Recommend pulmonologist referral if abnormalities on LDCT.
     OR
    b.   Chest x-ray with B read performed by NIOSH-certified B reader (or low dose CT chest if PLHCP deems appropriate): for workers not performing high exposure trigger tasks who are exposed at or above the action level for ≥30 days/year.
  4. ​​​​​​Spirometry, including FEV1, FVC, and FEV1/FVC ratio, performed by a NIOSH-certified technician.​​​
  5. Latent TB test (initial exam only) per CDC Guidelines​​​​​​
  6. Additional or more frequent testing, as recommended by the PLHCP.​

​​​​Following the exam, providers must provide written medical opinions with the following information to employers and employees:

Employers (see suggested template below)

a. The date of the examination
b. A statement that the examination has met the requirements of this section
c. Any recommended limitations on the employee's use of respirators
d. For employees exposed to high-exposure trigger tasks, an opinion on whether a supplied-air respirator is needed for the employee.
i. Required for any worker diagnosed with confirmed silicosis, suspected silicosis (see below definition), or whenever the PLHCP or specialist recommends use of a supplied-air respirator. Note that the report to the employer should not include information about specific diagnoses.
e. Any recommended limitations on the employee's exposure to respirable crystalline silica, including during high-exposure trigger tasks
f. A statement that the employee should be examined by a specialist (occupational medicine or pulmonology), if deemed appropriate by ​the PLHCP.

​​Employee (see suggested template below)

​Include all information shared with the employer, and

g. Overall results of the exam, including results of the chest CT, if performed.
h. The presence of any medical conditions “that would place the employee at increased risk of material impairment to health” from further silica exposure, including any diagnosis of silicosis, suspected silicosis, or lung cancer.
i. The presence of any medical conditions that may require further evaluation or treatment.

​Reporting requirements to ​Cal/OSHA and Public Health:

For all silica medical exams, even if results are normal:

  • Report to the California Department of Public Health within 14 days of the exam.
  • Send name and date of birth of the examined employee, as well as a copy of the PLHCP’s written medical report for the employee (see suggested template below)
  • Methods for reporting:

​​​​​​For patients diagnosed with silicosis or lung cancer

​​​​Appendix​: Resources and Templates​​

Employee Questionnaire Te​mplate (Word): A questionnaire for clinical and occupational history collection.

Report of Results to Employee and CDPH (PDF): A template that can be used for the employee report and sent to CDPH for reporting

Report of Results to Employee and CDPH (Spanish, PDF)​
Report of Results to Empl​oyer (Word)​​: A template that can be used for the employer report
Case Reporting and Links

Contact Information for CDPH silica medical exam reporting:

To report cases of silicosis or lung cancer to Cal/OSHA, call the relevant Cal/OSHA district office.

Key Definitions​​

Chest X-ray with NIOSH B read: Chest X-ray classified by an individual certified by the National Institute for Occupational Safety and Health as B reader. A classification of >=1/0 is abnormal.

High exposure trigger tasks: Machining, crushing, cutting, drilling, abrading, abrasive blasting, grinding, chiseling, carving, gouging, polishing, buffing, fracturing, intentional breaking, or intentional chipping of artificial stone that contains more than 0.1 percent by weight crystalline silica, or other silica containing products, including natural stone, that contains more than 10 percent by weight crystalline silica. High-exposure trigger tasks also includes clean up, disturbing, or handling of wastes, dusts, residues, debris, or other materials created during the above-listed tasks.
  • ​Workers involved in countertop fabrication or similar tasks are likely to fall under this category.
PLHCP: Physician or other licensed healthcare professional conducting the silicosis exam.

Specialist: American Board Certified Specialist in Pulmonary Disease or an American Board Certified Specialist in Occupational Medicine.

Supplied air-respirator: Full face, tight-fitting supplied-air respirator in pressure-demand or other positive pressure mode with air source located in an area that is free of respirable crystalline silica and other airborne contaminants. 

Suspected silicosis: 
  • Respirable crystalline silica exposure and one or more of the following symptoms for 14 or more days unless the symptom is explained by another illness: cough, difficulty breathing, fatigue, shortness of breath, chest pain, weakness, fever, or unexplained weight loss;
  • OR clinical findings suggestive of silicosis
  • OR respirable crystalline silica exposure with abnormal spirometry regardless of symptoms that is not yet a confirmed silicosis case

Confirmed Silicosis: One or more of the following categories:

​A. Written Diagnosis of Silicosis made by a PLHCP AND one or more:
​B. Death Certificate
​C. Exposure to RCS* AND one or more:
  • ​One or more:
    • A chest X-ray with NIOSH B-read classified as abnormal; or
    • CT scan consistent with silicosis;
      or
    • Lung histopathology consistent with silicosis
  • ​​Lists silicosis or or pneumoconiosis from silica dust as an underlying or contributing cause of death



  • ​Chest X-ray (or other imaging technique, such as a CT scan) showing abnormalities interpreted as consistent with silicosis;
    or
  • Lung histopathology consistent with silicosis.

​


* RCS: Respirable Crystalline Silica

Medical Surveillance Algorithm

Diagram of medical surveillance algorithm for silicosis
*High exposure trigger tasks at least 30 days/year, regardless of exposure measurements
**Occupationally exposed to respirable crystalline silica at or above the action level for 30 or more days per year

CDPH OHB: California Department of Public Health, Occupational Health Branch
CT: Computed tomography
CXR: Chest X-ray
PLHCP: Physician or Other Licensed Health Care Professional
RCS: Respirable crystalline silica
TB: Tuberculosis



​


Page Last Updated :